Air-source heat pumps: what they are, how they work, types, consumption and cost

The term ‘aerothermal energy’ refers to harnessing the thermal energy contained in ambient air using a heat pump. In homes and buildings, the term is mainly used to refer to air-to-water heat pump systems capable of providing heating, domestic hot water (DHW) and, if the system is reversible, cooling as well.

It works by transferring thermal energy from outdoors to indoors through a refrigerant circuit, rather than “producing” heat with electricity as an electric resistance heater does. This is why it can deliver several units of heat for each unit of electricity consumed. The European Commission notes that modern heat pumps are approximately 3 to 5 times more efficient than a gas boiler, although actual performance depends on outdoor temperature, design, heat emitters, flow temperature and maintenance.

IDAE defines aerothermal energy as energy stored as heat in ambient air and recognises that heat pumps can capture this renewable energy under certain conditions. In practice, air-source heat pumps have become one of the main technologies for electrifying building heating and reducing fossil fuel consumption.

However, not all installations perform in the same way. A well-insulated home with underfloor heating can achieve very high efficiencies, while a retrofit with radiators that require high-temperature water may need a specific heat pump and consume more electricity. Before comparing prices or savings, it is therefore important to understand which type of air-source heat pump is being installed, what temperature the building requires and its actual heat demand.

How do air-source heat pumps work?

An air-source heat pump uses a refrigeration cycle similar to that of a fridge or air conditioner, but can operate in reverse. In heating mode, the refrigerant absorbs heat from the outdoor air in the evaporator, even when outdoor temperatures are low. The compressor raises the refrigerant’s pressure and temperature, after which the condenser transfers this energy to the water in the heating circuit or to the indoor air.

In an air-to-water installation, this hot water can supply underfloor heating, fan coils or low-temperature radiators. With a hot water cylinder, the same heat pump can also produce DHW for showers and taps. In summer, if the unit is reversible, the cycle can be reversed to remove heat from the building and cool it. Efficiency is usually expressed through COP and SCOP. COP represents performance under specific conditions, while SCOP reflects performance over an entire heating season. European regulations define SCOP as the ratio of reference annual heating demand to the unit’s annual energy consumption.

SCOP ≈ heat energy delivered during the season / electricity consumed

In simplified terms, a SCOP of 4 means that the system delivers around 4 kWh of heat for every 1 kWh of electricity consumed over the season. It does not mean that the remaining 75% of the energy is “free” in economic terms: it comes from ambient heat captured by the heat pump. IDAE considers ambient energy captured by heat pumps renewable when the criteria established by European regulations are met.

Air-source heat pump types and configurations

The term aerothermal energy covers different configurations. In Spain, it is particularly associated with air-to-water heat pumps, but technically there are also air-to-air systems that harness energy from outdoor air. Air-to-water systems can also use monobloc or split architectures, high-temperature units and hybrid solutions.

Air-to-water

Extracts energy from outdoor air and transfers it to a water circuit. It can supply underfloor heating, fan coils, radiators and a DHW cylinder. This is the configuration normally referred to as ‘aerotermia’ in the Spanish residential market.

Air-to-air

Transfers heat between outdoor and indoor air. This is the principle behind a reversible air conditioner with a heat pump. It is efficient for heating and cooling rooms, but normally neither produces DHW nor uses a water circuit.

Monobloc

All the main components of the refrigerant circuit are housed in the outdoor unit. Water circulates indoors, which usually simplifies refrigerant installation work. Frost protection and the water circuit route must be designed correctly.

Split system

The refrigerant circuit connects an outdoor unit to an indoor hydraulic module. This provides greater installation flexibility, but requires refrigerant handling by qualified personnel and space for the indoor unit.

High temperature

Units designed to produce water at higher temperatures than a standard heat pump normally provides. They can facilitate retrofits using existing radiators, although higher flow temperatures usually mean lower seasonal efficiency.

Hybrid system

Combines an air-source heat pump with another heat source, usually a boiler. The controller decides which generator to use according to temperature, demand, energy cost or required output. It can be useful in complex retrofits.

Underfloor heating

This is not a type of heat pump, but a heat emitter particularly well suited to air-source systems because it operates at relatively low water temperatures. This supports high COP and SCOP values and provides very uniform thermal comfort.

Fan coils

A fan blows air through a hot or chilled water coil. Fan coils provide responsive heating and cooling and are a common solution when reversible climate control is required without installing underfloor heating.

Low-temperature radiators

Designed to deliver sufficient heat output with cooler water than conventional radiators. They can make it easier to replace a boiler with an air-source heat pump without installing underfloor heating throughout the home.

Main components of an air-source heat pump installation

Although configurations vary by manufacturer and building, an air-to-water installation usually includes several components working as one system. The outdoor unit normally contains a fan, evaporator and compressor; the refrigerant circuit carries the refrigerant; and the hydraulic module manages heat transfer to the building’s water. In split systems, some of these components are located inside the home.

ComponentMain function
Outdoor unitCaptures energy from the air and houses the fan, heat exchanger and usually the compressor.
CompressorRaises refrigerant pressure and temperature and is one of the main electricity consumers.
Heat exchangersAllow heat to be captured from outdoors and transferred to the indoor circuit.
Hydraulic moduleManages water flow, circulation and control for heating, cooling or DHW.
DHW cylinderStores domestic hot water to cover peaks in demand.
Buffer tankNot always required; helps stabilise system flow rates, operating cycles and water volume.
Pumps, valves and expansion vesselControl circulation, pressure and distribution between the different circuits.
Heat emittersUnderfloor heating, fan coils or radiators transfer thermal energy to rooms.
Controls and thermostatsManage temperatures, schedules, weather compensation curves, zones and priorities between heating and DHW.

How much electricity does an air-source heat pump use?

There is no annual consumption figure that applies to every home. It depends on the building’s heat demand, climate, insulation, floor area, number of occupants, setpoint temperature, DHW production, emitter type and the heat pump’s seasonal efficiency. It is therefore more useful to calculate consumption from the heat requirement.

Approximate electricity consumption = annual heat demand / SCOP

If a home needs 10,000 kWh of heat per year for heating and the system operates with a SCOP of 4, the associated electricity consumption would be approximately 2,500 kWh/year. With a heat demand of 15,000 kWh, it would be around 3,750 kWh of electricity. Consumption for DHW, cooling, auxiliary pumps and, when used, the backup electric resistance heater would need to be added to this figure.

Annual heat demandSCOP 3SCOP 4SCOP 5
6,000 kWh2,000 kWh of electricity1,500 kWh1,200 kWh
10,000 kWh3,333 kWh2,500 kWh2,000 kWh
15,000 kWh5,000 kWh3,750 kWh3,000 kWh

The European Commission notes that modern heat pumps can be three to five times more efficient than gas boilers. However, performance deteriorates when the difference between the outdoor temperature and the required flow temperature is very large. This is why a heat pump usually works better with underfloor heating or low-temperature emitters than when forced to produce very hot water. European Commission.

Air-source heat pump prices: installation costs

The price depends much more on the complete installation than on the heat pump alone. Capacity, the DHW cylinder, number of circuits, need for a buffer tank, plumbing work, electrical distribution board modifications and, above all, the heat emitters can significantly change the budget. As an indicative market reference for Spain in 2026, a complete air-to-water installation for heating and DHW may fall approximately within these ranges:

Indicative property typeTypical capacityApproximate installed cost
70 m² flat4–6 kW€6,500–9,500
100 m² flat6–8 kW€7,000–12,000
150 m² single-family home10–12 kW€12,000–18,000
200 m² single-family home14–16 kW€17,000–22,000

These figures are indicative and do not replace a survey. Installing underfloor heating from scratch can add approximately €40–70/m² in works, while reusing compatible emitters can greatly reduce the cost. The initial investment forms part of the system’s CAPEX while electricity, maintenance and replacements determine its OPEX. The above ranges are based on market references published in 2026 and may vary by region, manufacturer and installation complexity. 2026 price reference.

Advantages and disadvantages of air-source heat pumps

AdvantagesDisadvantages
High seasonal efficiency when the system is correctly sized.Higher initial investment than simple solutions such as a split air conditioner.
Can integrate heating, cooling and DHW in a single system.Performance depends on the climate and required flow temperature.
Requires no on-site combustion or gas or heating oil storage.Requires an outdoor unit, with noise, location and airflow needing assessment.
Works particularly well with underfloor heating and low-temperature emitters.Retrofits with old radiators may require replacement emitters or high-temperature units.
Can be combined with photovoltaic self-consumption to reduce purchases of grid electricity.May require a review of the contracted electrical capacity and the home’s distribution board.
Enables heat demand to be electrified and renewable ambient energy to be used.Incorrect sizing, short cycling or excessive use of electric resistance heating can worsen consumption and comfort.

Air-to-water heat pumps vs air conditioning: key differences

The distinction can be confusing because both use the same thermodynamic principle. A reversible air conditioner is an air-to-air heat pump and, in a broad technical sense, also harnesses aerothermal energy. However, in Spanish commercial usage, ‘aerotermia’ normally refers to an air-to-water system.

FeatureAir-to-water heat pumpAir-to-air air conditioning
Indoor heat transfer mediumWaterAir
HeatingYesYes, if it is a reversible heat pump
CoolingYes, with compatible floor cooling or fan coilsYes
DHWYesNot normally
Heat emittersUnderfloor heating, radiators, fan coilsSplit, multi-split or ducted systems
Initial investmentHigherLower
Typical applicationIntegrated heating, cooling and DHW systemDirect air heating and cooling for one or more zones

It therefore cannot be said that an air-to-water system is always “better” than air conditioning. For a small flat without a water circuit, a good air-to-air system may be cheaper and more efficient. For a new home that needs heating, cooling and DHW, an air-to-water heat pump offers integration that a conventional split unit does not provide.

Air-source heat pumps with solar panels: why they work well together

Air-source heat pumps electrify demand that might previously have been met by gas or heating oil, while a photovoltaic installation generates electricity in the building itself. This combination makes it possible to increase self-consumption, particularly if controls shift DHW production or some heating and cooling to sunny hours. However, the match is not perfect: peak heating demand usually occurs in winter and during hours without sunshine. A photovoltaic installation therefore does not automatically eliminate the heat pump’s electricity consumption. The design must analyse hourly profiles, thermal storage and electricity tariffs and, in more complex buildings, can be integrated into an Energy Management System.

What determines whether an air-source heat pump uses little or a lot of electricity

Final consumption depends less on a catalogue figure than on how the building, climate and system interact. Insulation and air leakage determine how much energy the home needs; emitter size determines the required water flow temperature; the weather compensation curve controls how that temperature changes with outdoor conditions; and unit sizing determines how much time it spends modulating rather than switching on and off.

Other factors include use of the backup electric resistance heater, defrost cycles on cold, damp days, the selected DHW temperature and occupants’ habits. An efficient installation is not simply a matter of buying a heat pump with a high COP: it requires thermal sizing, suitable emitters, correct controls and the lowest possible flow temperature.