{"id":93037,"date":"2026-11-17T17:08:02","date_gmt":"2026-11-17T16:08:02","guid":{"rendered":"https:\/\/energyear.com\/es\/?p=93037"},"modified":"2026-11-17T17:35:42","modified_gmt":"2026-11-17T16:35:42","slug":"capacity-factor-factor-capacidad-que-es-calculo","status":"publish","type":"post","link":"https:\/\/energyear.com\/it\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/","title":{"rendered":"Capacity Factor o fattore di capacit\u00e0: che cos\u2019\u00e8, formula e calcolo"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"93037\" class=\"elementor elementor-93037\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cd7ed7e e-con-full e-flex e-con e-parent\" data-id=\"cd7ed7e\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t<div class=\"elementor-element elementor-element-5022b9f e-con-full e-flex e-con e-child\" data-id=\"5022b9f\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a80ec7d elementor-widget elementor-widget-heading\" data-id=\"a80ec7d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Capacity Factor o factor de capacidad: qu\u00e9 es, f\u00f3rmula y c\u00f3mo se calcula<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ebe8bf9 elementor-widget elementor-widget-text-editor\" data-id=\"ebe8bf9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>El <strong>Capacity Factor<\/strong> o <strong>factor de capacidad<\/strong> mide qu\u00e9 proporci\u00f3n de la energ\u00eda m\u00e1xima te\u00f3rica que podr\u00eda producir una instalaci\u00f3n durante un periodo determinado ha sido realmente generada. Es una de las m\u00e9tricas m\u00e1s utilizadas para comparar el aprovechamiento de activos de generaci\u00f3n como plantas solares, parques e\u00f3licos, centrales hidroel\u00e9ctricas, geot\u00e9rmicas, nucleares o t\u00e9rmicas.<\/p><p>La idea es sencilla: una planta de 100 MW que pudiera operar a plena potencia durante las 8.760 horas de un a\u00f1o producir\u00eda, en teor\u00eda, 876.000 MWh. En la pr\u00e1ctica nunca ocurre exactamente as\u00ed. El recurso solar o e\u00f3lico var\u00eda, existen mantenimientos, indisponibilidades, p\u00e9rdidas, restricciones de red y, en tecnolog\u00edas despachables, decisiones de mercado que hacen que la central no funcione continuamente al 100 %.<\/p><p>Por eso, el factor de capacidad conecta dos variables que a menudo se confunden: potencia instalada y energ\u00eda realmente producida. Dos plantas con la misma potencia nominal pueden generar cantidades de electricidad muy diferentes a lo largo del a\u00f1o y, por tanto, tener factores de capacidad muy distintos.<\/p><p>Esta m\u00e9trica es especialmente relevante en estudios de producci\u00f3n, valoraci\u00f3n de activos, planificaci\u00f3n del sistema y c\u00e1lculo del <span style=\"text-decoration: underline;\"><span style=\"color: #000080;\"><a style=\"color: #000080;\" href=\"https:\/\/energyear.com\/es\/diccionario-energetico\/lcoe-que-es-como-se-calcula-coste-energia\/\"><strong>LCOE<\/strong><\/a><\/span><\/span>, porque un activo que utiliza m\u00e1s horas equivalentes de su capacidad instalada reparte sus costes fijos entre un mayor n\u00famero de MWh. Sin embargo, un factor de capacidad alto no significa autom\u00e1ticamente que el proyecto sea m\u00e1s rentable ni que la tecnolog\u00eda sea m\u00e1s eficiente: hay que analizar tambi\u00e9n precios capturados, CAPEX, OPEX, disponibilidad, degradaci\u00f3n y riesgo de mercado.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8e887f1 e-con-full e-flex e-con e-child\" data-id=\"8e887f1\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-47a1915 e-con-full e-flex e-con e-parent\" data-id=\"47a1915\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ce8f8da elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"ce8f8da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h2>\u00bfC\u00f3mo se calcula el factor de capacidad?<\/h2><p>El c\u00e1lculo compara la energ\u00eda realmente producida durante un periodo con la energ\u00eda que habr\u00eda generado el activo si hubiera operado a su potencia nominal de forma continua durante todas las horas de ese mismo periodo.<\/p><p style=\"text-align: center; font-size: 20px;\"><strong>Factor de capacidad (%) = Energ\u00eda real generada \/ (Potencia nominal \u00d7 horas del periodo) \u00d7 100<\/strong><\/p><p>Si se analiza un a\u00f1o normal se utilizan habitualmente 8.760 horas. En un a\u00f1o bisiesto ser\u00edan 8.784. Para periodos mensuales o diarios debe utilizarse el n\u00famero real de horas del intervalo analizado. Por ejemplo, una planta e\u00f3lica de 100 MW que produce 350 GWh durante un a\u00f1o habr\u00eda generado 350.000 MWh. Su producci\u00f3n m\u00e1xima te\u00f3rica ser\u00eda 100 MW \u00d7 8.760 h = 876.000 MWh. El c\u00e1lculo ser\u00eda:<\/p><p style=\"text-align: center; font-size: 20px;\"><strong>350.000 MWh \/ 876.000 MWh \u00d7 100 = 40,0 %<\/strong><\/p><p>Ese 40 % no significa que la planta haya operado exactamente al 40 % de potencia cada hora. Puede haber pasado muchas horas cerca de su potencia m\u00e1xima, otras a producci\u00f3n parcial y otras completamente parada. El factor de capacidad resume todo ese comportamiento en una \u00fanica cifra equivalente.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c3db85 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"5c3db85\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<div id=\"energyear-capacity-factor\">\n  <style>\n    #energyear-capacity-factor {\n      --navy: #111a5c;\n      --blue: #1267dc;\n      --cyan: #24a8df;\n      --violet: #7047d7;\n      --orange: #f07822;\n      --yellow: #f6b91f;\n      --text: #172033;\n      --muted: #667085;\n      --border: #e4e9f2;\n      --soft: #f7f9fc;\n      --white: #ffffff;\n\n      font-family: Arial, Helvetica, sans-serif;\n      color: var(--text);\n      max-width: 1100px;\n      margin: 0 auto;\n    }\n\n    #energyear-capacity-factor * {\n      box-sizing: border-box;\n    }\n\n    #energyear-capacity-factor .cf-shell {\n      background: var(--white);\n      border: 1px solid var(--border);\n      border-radius: 22px;\n      overflow: hidden;\n      box-shadow: 0 12px 35px rgba(17, 26, 92, 0.08);\n    }\n\n    #energyear-capacity-factor .cf-header {\n      padding: 30px 32px 24px;\n      border-bottom: 1px solid var(--border);\n    }\n\n    #energyear-capacity-factor .cf-kicker {\n      color: var(--navy);\n      font-size: 13px;\n      font-weight: 800;\n      letter-spacing: 1.6px;\n      text-transform: uppercase;\n      margin-bottom: 8px;\n    }\n\n    #energyear-capacity-factor .cf-title {\n      margin: 0;\n      font-size: clamp(27px, 4vw, 42px);\n      line-height: 1.05;\n      color: var(--navy);\n      font-weight: 800;\n    }\n\n    #energyear-capacity-factor .cf-title span {\n      background: linear-gradient(\n        90deg,\n        var(--blue),\n        var(--cyan),\n        var(--violet),\n        var(--orange),\n        var(--yellow)\n      );\n      -webkit-background-clip: text;\n      background-clip: text;\n      color: transparent;\n    }\n\n    #energyear-capacity-factor .cf-line {\n      width: 180px;\n      height: 4px;\n      border-radius: 50px;\n      margin: 16px 0;\n      background: linear-gradient(\n        90deg,\n        var(--blue),\n        var(--cyan),\n        var(--violet),\n        var(--orange),\n        var(--yellow)\n      );\n    }\n\n    #energyear-capacity-factor .cf-intro {\n      margin: 0;\n      max-width: 780px;\n      color: var(--muted);\n      font-size: 15px;\n      line-height: 1.65;\n    }\n\n    #energyear-capacity-factor .cf-grid {\n      display: grid;\n      grid-template-columns: minmax(0, 1fr) minmax(320px, 0.85fr);\n      gap: 0;\n    }\n\n    #energyear-capacity-factor .cf-inputs,\n    #energyear-capacity-factor .cf-results {\n      padding: 32px;\n    }\n\n    #energyear-capacity-factor .cf-results {\n      background:\n        radial-gradient(circle at 100% 0%, rgba(36,168,223,.09), transparent 38%),\n        var(--soft);\n      border-left: 1px solid var(--border);\n    }\n\n    #energyear-capacity-factor .cf-section-title {\n      margin: 0 0 22px;\n      color: var(--navy);\n      font-size: 20px;\n      font-weight: 800;\n    }\n\n    #energyear-capacity-factor .cf-field {\n      margin-bottom: 20px;\n    }\n\n    #energyear-capacity-factor label {\n      display: block;\n      margin-bottom: 8px;\n      color: var(--navy);\n      font-size: 14px;\n      font-weight: 700;\n    }\n\n    #energyear-capacity-factor .cf-control-row {\n      display: grid;\n      grid-template-columns: minmax(0, 1fr) 105px;\n      gap: 10px;\n    }\n\n    #energyear-capacity-factor input,\n    #energyear-capacity-factor select {\n      width: 100%;\n      min-height: 48px;\n      border: 1px solid #d8deea;\n      border-radius: 10px;\n      background: #fff;\n      color: var(--text);\n      padding: 0 13px;\n      font-size: 15px;\n      outline: none;\n      transition: border-color .18s ease, box-shadow .18s ease;\n    }\n\n    #energyear-capacity-factor input:focus,\n    #energyear-capacity-factor select:focus {\n      border-color: var(--blue);\n      box-shadow: 0 0 0 3px rgba(18, 103, 220, 0.10);\n    }\n\n    #energyear-capacity-factor .cf-help {\n      margin: 7px 0 0;\n      color: var(--muted);\n      font-size: 12px;\n      line-height: 1.45;\n    }\n\n    #energyear-capacity-factor .cf-period-grid {\n      display: grid;\n      grid-template-columns: 1fr 1fr;\n      gap: 10px;\n    }\n\n    #energyear-capacity-factor .cf-button {\n      width: 100%;\n      border: 0;\n      border-radius: 11px;\n      min-height: 51px;\n      cursor: pointer;\n      color: #fff;\n      font-size: 15px;\n      font-weight: 800;\n      margin-top: 5px;\n      background: linear-gradient(90deg, var(--blue), var(--violet));\n      transition: transform .15s ease, opacity .15s ease;\n    }\n\n    #energyear-capacity-factor .cf-button:hover {\n      opacity: .94;\n      transform: translateY(-1px);\n    }\n\n    #energyear-capacity-factor .cf-main-result {\n      border-radius: 18px;\n      padding: 26px;\n      background: var(--navy);\n      color: white;\n      margin-bottom: 16px;\n    }\n\n    #energyear-capacity-factor .cf-main-label {\n      font-size: 12px;\n      font-weight: 700;\n      letter-spacing: 1.2px;\n      text-transform: uppercase;\n      opacity: .78;\n    }\n\n    #energyear-capacity-factor .cf-number {\n      display: block;\n      margin-top: 6px;\n      font-size: clamp(46px, 7vw, 68px);\n      line-height: 1;\n      font-weight: 800;\n    }\n\n    #energyear-capacity-factor .cf-number small {\n      font-size: .42em;\n    }\n\n    #energyear-capacity-factor .cf-bar {\n      height: 10px;\n      background: rgba(255,255,255,.17);\n      border-radius: 50px;\n      overflow: hidden;\n      margin-top: 20px;\n    }\n\n    #energyear-capacity-factor .cf-bar-fill {\n      height: 100%;\n      width: 0%;\n      border-radius: 50px;\n      background: linear-gradient(\n        90deg,\n        var(--cyan),\n        var(--violet),\n        var(--orange),\n        var(--yellow)\n      );\n      transition: width .4s ease;\n    }\n\n    #energyear-capacity-factor .cf-result-grid {\n      display: grid;\n      grid-template-columns: 1fr 1fr;\n      gap: 12px;\n    }\n\n    #energyear-capacity-factor .cf-card {\n      padding: 17px;\n      border: 1px solid var(--border);\n      border-radius: 14px;\n      background: #fff;\n    }\n\n    #energyear-capacity-factor .cf-card-label {\n      display: block;\n      color: var(--muted);\n      font-size: 12px;\n      line-height: 1.4;\n      margin-bottom: 6px;\n    }\n\n    #energyear-capacity-factor .cf-card-value {\n      display: block;\n      color: var(--navy);\n      font-size: 22px;\n      line-height: 1.2;\n      font-weight: 800;\n    }\n\n    #energyear-capacity-factor .cf-status {\n      margin-top: 16px;\n      padding: 14px 16px;\n      border-radius: 12px;\n      background: #eef6ff;\n      border-left: 4px solid var(--blue);\n      color: #344054;\n      font-size: 13px;\n      line-height: 1.55;\n    }\n\n    #energyear-capacity-factor .cf-formula {\n      padding: 22px 32px;\n      border-top: 1px solid var(--border);\n      background: #fff;\n      text-align: center;\n    }\n\n    #energyear-capacity-factor .cf-formula-title {\n      color: var(--muted);\n      text-transform: uppercase;\n      font-size: 11px;\n      font-weight: 800;\n      letter-spacing: 1px;\n      margin-bottom: 7px;\n    }\n\n    #energyear-capacity-factor .cf-formula-text {\n      color: var(--navy);\n      font-weight: 800;\n      font-size: 16px;\n      line-height: 1.5;\n    }\n\n    @media (max-width: 800px) {\n      #energyear-capacity-factor .cf-grid {\n        grid-template-columns: 1fr;\n      }\n\n      #energyear-capacity-factor .cf-results {\n        border-left: 0;\n        border-top: 1px solid var(--border);\n      }\n\n      #energyear-capacity-factor .cf-header,\n      #energyear-capacity-factor .cf-inputs,\n      #energyear-capacity-factor .cf-results {\n        padding: 24px;\n      }\n    }\n\n    @media (max-width: 480px) {\n      #energyear-capacity-factor .cf-control-row,\n      #energyear-capacity-factor .cf-period-grid,\n      #energyear-capacity-factor .cf-result-grid {\n        grid-template-columns: 1fr;\n      }\n    }\n  <\/style>\n\n  <div class=\"cf-shell\">\n    <div class=\"cf-header\">\n      <div class=\"cf-kicker\">Energyear \u00b7 Diccionario energ\u00e9tico<\/div>\n\n      <h2 class=\"cf-title\">\n        Calculadora de <span>Factor de Capacidad<\/span>\n      <\/h2>\n\n      <div class=\"cf-line\"><\/div>\n\n      <p class=\"cf-intro\">\n        Introduce la energ\u00eda producida, la potencia nominal y el periodo analizado.\n        La calculadora compara la generaci\u00f3n real con la producci\u00f3n m\u00e1xima te\u00f3rica\n        que tendr\u00eda el activo si funcionara continuamente a plena potencia.\n      <\/p>\n    <\/div>\n\n    <div class=\"cf-grid\">\n\n      <div class=\"cf-inputs\">\n        <h3 class=\"cf-section-title\">Datos del activo<\/h3>\n\n        <div class=\"cf-field\">\n          <label for=\"cf-energy\">Energ\u00eda generada<\/label>\n\n          <div class=\"cf-control-row\">\n            <input\n              id=\"cf-energy\"\n              type=\"number\"\n              min=\"0\"\n              step=\"any\"\n              value=\"350\"\n              placeholder=\"Ej. 350\"\n            >\n\n            <select id=\"cf-energy-unit\">\n              <option value=\"0.001\">kWh<\/option>\n              <option value=\"1\">MWh<\/option>\n              <option value=\"1000\" selected>GWh<\/option>\n              <option value=\"1000000\">TWh<\/option>\n            <\/select>\n          <\/div>\n\n          <p class=\"cf-help\">\n            Producci\u00f3n el\u00e9ctrica real registrada durante el periodo.\n          <\/p>\n        <\/div>\n\n        <div class=\"cf-field\">\n          <label for=\"cf-power\">Potencia nominal<\/label>\n\n          <div class=\"cf-control-row\">\n            <input\n              id=\"cf-power\"\n              type=\"number\"\n              min=\"0\"\n              step=\"any\"\n              value=\"100\"\n              placeholder=\"Ej. 100\"\n            >\n\n            <select id=\"cf-power-unit\">\n              <option value=\"0.001\">kW<\/option>\n              <option value=\"1\" selected>MW<\/option>\n              <option value=\"1000\">GW<\/option>\n            <\/select>\n          <\/div>\n\n          <p class=\"cf-help\">\n            Usa siempre la misma base al comparar activos. En fotovoltaica,\n            especifica si utilizas potencia AC o potencia pico DC.\n          <\/p>\n        <\/div>\n\n        <div class=\"cf-field\">\n          <label>Periodo analizado<\/label>\n\n          <div class=\"cf-period-grid\">\n            <select id=\"cf-period\">\n              <option value=\"8760\" selected>A\u00f1o normal \u00b7 8.760 h<\/option>\n              <option value=\"8784\">A\u00f1o bisiesto \u00b7 8.784 h<\/option>\n              <option value=\"730\">Mes medio \u00b7 730 h<\/option>\n              <option value=\"720\">30 d\u00edas \u00b7 720 h<\/option>\n              <option value=\"744\">31 d\u00edas \u00b7 744 h<\/option>\n              <option value=\"168\">7 d\u00edas \u00b7 168 h<\/option>\n              <option value=\"24\">1 d\u00eda \u00b7 24 h<\/option>\n              <option value=\"custom\">Personalizado<\/option>\n            <\/select>\n\n            <input\n              id=\"cf-hours\"\n              type=\"number\"\n              min=\"0\"\n              step=\"any\"\n              value=\"8760\"\n              aria-label=\"Horas del periodo\"\n            >\n          <\/div>\n\n          <p class=\"cf-help\">\n            Puedes seleccionar un periodo est\u00e1ndar o introducir las horas manualmente.\n          <\/p>\n        <\/div>\n\n        <button id=\"cf-calculate\" class=\"cf-button\" type=\"button\">\n          Calcular factor de capacidad\n        <\/button>\n      <\/div>\n\n      <div class=\"cf-results\">\n        <h3 class=\"cf-section-title\">Resultado<\/h3>\n\n        <div class=\"cf-main-result\">\n          <div class=\"cf-main-label\">Factor de capacidad<\/div>\n\n          <span class=\"cf-number\">\n            <span id=\"cf-factor\">40,0<\/span><small>%<\/small>\n          <\/span>\n\n          <div class=\"cf-bar\">\n            <div id=\"cf-bar-fill\" class=\"cf-bar-fill\"><\/div>\n          <\/div>\n        <\/div>\n\n        <div class=\"cf-result-grid\">\n          <div class=\"cf-card\">\n            <span class=\"cf-card-label\">Horas equivalentes a plena carga<\/span>\n            <span class=\"cf-card-value\" id=\"cf-full-hours\">3.500 h<\/span>\n          <\/div>\n\n          <div class=\"cf-card\">\n            <span class=\"cf-card-label\">Energ\u00eda m\u00e1xima te\u00f3rica<\/span>\n            <span class=\"cf-card-value\" id=\"cf-max-energy\">876 GWh<\/span>\n          <\/div>\n\n          <div class=\"cf-card\">\n            <span class=\"cf-card-label\">Energ\u00eda real producida<\/span>\n            <span class=\"cf-card-value\" id=\"cf-real-energy\">350 GWh<\/span>\n          <\/div>\n\n          <div class=\"cf-card\">\n            <span class=\"cf-card-label\">Diferencia frente al m\u00e1ximo te\u00f3rico<\/span>\n            <span class=\"cf-card-value\" id=\"cf-unused-energy\">526 GWh<\/span>\n          <\/div>\n        <\/div>\n\n        <div id=\"cf-status\" class=\"cf-status\">\n          Un factor de capacidad del 40 % significa que la producci\u00f3n obtenida\n          equivale a operar a potencia nominal durante aproximadamente el 40 %\n          de todas las horas del periodo.\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/div>\n\n  <script>\n    (function () {\n      const root = document.getElementById(\"energyear-capacity-factor\");\n      if (!root) return;\n\n      const energyInput = root.querySelector(\"#cf-energy\");\n      const energyUnit = root.querySelector(\"#cf-energy-unit\");\n\n      const powerInput = root.querySelector(\"#cf-power\");\n      const powerUnit = root.querySelector(\"#cf-power-unit\");\n\n      const periodSelect = root.querySelector(\"#cf-period\");\n      const hoursInput = root.querySelector(\"#cf-hours\");\n\n      const calculateButton = root.querySelector(\"#cf-calculate\");\n\n      const factorOutput = root.querySelector(\"#cf-factor\");\n      const hoursOutput = root.querySelector(\"#cf-full-hours\");\n      const maxOutput = root.querySelector(\"#cf-max-energy\");\n      const realOutput = root.querySelector(\"#cf-real-energy\");\n      const unusedOutput = root.querySelector(\"#cf-unused-energy\");\n\n      const barFill = root.querySelector(\"#cf-bar-fill\");\n      const status = root.querySelector(\"#cf-status\");\n\n      function formatNumber(value, decimals) {\n        return new Intl.NumberFormat(\"es-ES\", {\n          minimumFractionDigits: decimals || 0,\n          maximumFractionDigits: decimals || 0\n        }).format(value);\n      }\n\n      function formatEnergy(mwh) {\n        if (Math.abs(mwh) >= 1000000) {\n          return formatNumber(mwh \/ 1000000, 2) + \" TWh\";\n        }\n\n        if (Math.abs(mwh) >= 1000) {\n          return formatNumber(mwh \/ 1000, 2) + \" GWh\";\n        }\n\n        if (Math.abs(mwh) >= 1) {\n          return formatNumber(mwh, 2) + \" MWh\";\n        }\n\n        return formatNumber(mwh * 1000, 2) + \" kWh\";\n      }\n\n      function calculate() {\n        const energyMWh =\n          parseFloat(energyInput.value || 0) *\n          parseFloat(energyUnit.value);\n\n        const powerMW =\n          parseFloat(powerInput.value || 0) *\n          parseFloat(powerUnit.value);\n\n        const hours = parseFloat(hoursInput.value || 0);\n\n        if (\n          energyMWh < 0 ||\n          powerMW <= 0 ||\n          hours <= 0 ||\n          !isFinite(energyMWh) ||\n          !isFinite(powerMW) ||\n          !isFinite(hours)\n        ) {\n          factorOutput.textContent = \"\u2014\";\n          hoursOutput.textContent = \"\u2014\";\n          maxOutput.textContent = \"\u2014\";\n          realOutput.textContent = \"\u2014\";\n          unusedOutput.textContent = \"\u2014\";\n          barFill.style.width = \"0%\";\n\n          status.textContent =\n            \"Introduce valores v\u00e1lidos para energ\u00eda, potencia y horas del periodo.\";\n\n          return;\n        }\n\n        const maxEnergyMWh = powerMW * hours;\n        const capacityFactor = (energyMWh \/ maxEnergyMWh) * 100;\n        const equivalentHours = energyMWh \/ powerMW;\n        const unusedEnergyMWh = maxEnergyMWh - energyMWh;\n\n        factorOutput.textContent = formatNumber(capacityFactor, 1);\n        hoursOutput.textContent =\n          formatNumber(equivalentHours, 0) + \" h\";\n\n        maxOutput.textContent = formatEnergy(maxEnergyMWh);\n        realOutput.textContent = formatEnergy(energyMWh);\n\n        unusedOutput.textContent =\n          unusedEnergyMWh >= 0\n            ? formatEnergy(unusedEnergyMWh)\n            : \"\u2014\";\n\n        barFill.style.width =\n          Math.min(Math.max(capacityFactor, 0), 100) + \"%\";\n\n        if (capacityFactor > 100) {\n          status.innerHTML =\n            \"<strong>Revisa los datos.<\/strong> El resultado supera el 100 %. \" +\n            \"Esto suele indicar que la potencia nominal, las unidades o el periodo \" +\n            \"utilizado no corresponden a la misma base que la energ\u00eda introducida.\";\n        } else if (capacityFactor >= 80) {\n          status.innerHTML =\n            \"El activo presenta un <strong>factor de capacidad muy elevado<\/strong>. \" +\n            \"Esto es habitual en algunas tecnolog\u00edas capaces de producir de manera \" +\n            \"continua, aunque debe interpretarse seg\u00fan el tipo de activo.\";\n        } else if (capacityFactor >= 50) {\n          status.innerHTML =\n            \"El activo presenta un <strong>factor de capacidad elevado<\/strong>. \" +\n            \"La potencia instalada se aprovecha durante una parte importante del periodo.\";\n        } else if (capacityFactor >= 25) {\n          status.innerHTML =\n            \"La producci\u00f3n equivale a operar a potencia nominal durante aproximadamente \" +\n            \"<strong>\" + formatNumber(capacityFactor, 1) + \"%<\/strong> de todas las horas analizadas.\";\n        } else {\n          status.innerHTML =\n            \"El factor de capacidad obtenido es relativamente bajo, pero esto \" +\n            \"<strong>no implica necesariamente un mal rendimiento<\/strong>. \" +\n            \"Debe compararse con valores propios de la tecnolog\u00eda, el recurso y el mercado.\";\n        }\n      }\n\n      periodSelect.addEventListener(\"change\", function () {\n        if (this.value !== \"custom\") {\n          hoursInput.value = this.value;\n        }\n\n        calculate();\n      });\n\n      hoursInput.addEventListener(\"input\", function () {\n        if (\n          periodSelect.value !== \"custom\" &&\n          Number(hoursInput.value) !== Number(periodSelect.value)\n        ) {\n          periodSelect.value = \"custom\";\n        }\n      });\n\n      calculateButton.addEventListener(\"click\", calculate);\n\n      [\n        energyInput,\n        energyUnit,\n        powerInput,\n        powerUnit,\n        hoursInput\n      ].forEach(function (element) {\n        element.addEventListener(\"input\", calculate);\n        element.addEventListener(\"change\", calculate);\n      });\n\n      if (\/^es(?:[-_]|$)\/i.test(document.documentElement.lang)) { calculate(); }\n    })();\n  <\/script>\n<\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15a63e6 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"15a63e6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h2>Horas equivalentes y factor de capacidad<\/h2><p>Otra forma habitual de expresar el mismo concepto son las horas equivalentes a plena carga. Se calculan dividiendo la producci\u00f3n anual entre la potencia nominal. En el ejemplo anterior, 350.000 MWh \/ 100 MW = 3.500 horas equivalentes. La relaci\u00f3n entre ambas m\u00e9tricas es directa:<\/p><p style=\"text-align: center; font-size: 20px;\"><strong>Factor de capacidad = Horas equivalentes \/ horas del periodo<\/strong><\/p><p>As\u00ed, 3.500 \/ 8.760 = 39,95 %. En fotovoltaica, esta idea guarda relaci\u00f3n con el <span style=\"text-decoration: underline;\"><span style=\"color: #000080;\"><a style=\"color: #000080;\" href=\"https:\/\/energyear.com\/es\/diccionario-energetico\/yield-energetico-energy-yield-assessment-fotovoltaica\/\"><strong>yield energ\u00e9tico<\/strong><\/a><\/span><\/span>, aunque no son exactamente la misma m\u00e9trica. El yield suele expresarse en kWh\/kWp y permite normalizar la producci\u00f3n respecto a la potencia pico DC instalada.<\/p><h2>Qu\u00e9 influye en el factor de capacidad<\/h2><p>El factor de capacidad final es el resultado de una combinaci\u00f3n de recurso, dise\u00f1o, disponibilidad, restricciones operativas y condiciones de mercado. Dos proyectos con la misma tecnolog\u00eda pueden tener valores muy diferentes incluso dentro del mismo pa\u00eds.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9fdde91 e-grid e-con-boxed e-con e-child\" data-id=\"9fdde91\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b08ea20 elementor-view-default elementor-position-block-start elementor-mobile-position-block-start elementor-widget elementor-widget-icon-box\" data-id=\"b08ea20\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\t\t\t<div class=\"elementor-icon-box-icon\">\n\t\t\t\t<span  class=\"elementor-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-sun\"><\/i>\t\t\t\t<\/span>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<h3 class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tRecurso energ\u00e9tico\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tRadiaci\u00f3n solar, velocidad del viento, caudal hidr\u00e1ulico, temperatura del recurso geot\u00e9rmico o disponibilidad de combustible condicionan cu\u00e1nta energ\u00eda puede producir realmente el activo.\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea16489 elementor-view-default elementor-position-block-start elementor-mobile-position-block-start elementor-widget elementor-widget-icon-box\" data-id=\"ea16489\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\t\t\t<div class=\"elementor-icon-box-icon\">\n\t\t\t\t<span  class=\"elementor-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-drafting-compass\"><\/i>\t\t\t\t<\/span>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<h3 class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tDise\u00f1o y configuraci\u00f3n\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tOrientaci\u00f3n, trackers, altura de buje, tama\u00f1o de rotor, DC\/AC ratio, eficiencia de equipos y dise\u00f1o hidr\u00e1ulico determinan cu\u00e1nto recurso puede transformarse en electricidad \u00fatil.\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c13d36 elementor-view-default elementor-position-block-start elementor-mobile-position-block-start elementor-widget elementor-widget-icon-box\" data-id=\"4c13d36\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\t\t\t<div class=\"elementor-icon-box-icon\">\n\t\t\t\t<span  class=\"elementor-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-tools\"><\/i>\t\t\t\t<\/span>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<h3 class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tDisponibilidad y mantenimiento\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tAver\u00edas, mantenimiento programado, fallos de componentes y tiempos de reparaci\u00f3n reducen las horas en las que el activo puede producir. Una buena estrategia de O&amp;M puede elevar el factor de capacidad real.\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c75b5a elementor-view-default elementor-position-block-start elementor-mobile-position-block-start elementor-widget elementor-widget-icon-box\" data-id=\"8c75b5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\t\t\t<div class=\"elementor-icon-box-icon\">\n\t\t\t\t<span  class=\"elementor-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-network-wired\"><\/i>\t\t\t\t<\/span>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<h3 class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tCurtailment y red\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tRestricciones de conexi\u00f3n, congesti\u00f3n, l\u00edmites de exportaci\u00f3n o instrucciones del operador pueden obligar a reducir producci\u00f3n disponible y disminuir el factor de capacidad observado.\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4691987 elementor-view-default elementor-position-block-start elementor-mobile-position-block-start elementor-widget elementor-widget-icon-box\" data-id=\"4691987\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\t\t\t<div class=\"elementor-icon-box-icon\">\n\t\t\t\t<span  class=\"elementor-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-chart-line\"><\/i>\t\t\t\t<\/span>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<h3 class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tDespacho y mercado\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tEn centrales t\u00e9rmicas, hidr\u00e1ulicas con embalse o activos despachables, la producci\u00f3n depende tambi\u00e9n de precios, costes variables, combustible, reservas y decisiones operativas, no solo de la capacidad t\u00e9cnica.\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-96f476e elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"96f476e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h2>Factores de capacidad t\u00edpicos por tecnolog\u00eda<\/h2><p>No existe un factor de capacidad \u201ccorrecto\u201d para cada tecnolog\u00eda. Los valores cambian seg\u00fan recurso, geograf\u00eda, dise\u00f1o, antig\u00fcedad, disponibilidad y metodolog\u00eda. Aun as\u00ed, los promedios globales permiten entender las diferencias estructurales entre tecnolog\u00edas.<\/p><table><thead><tr><th>Tecnolog\u00eda<\/th><th>Referencia global reciente<\/th><th>Aspecto clave<\/th><\/tr><\/thead><tbody><tr><td><strong>Solar fotovoltaica<\/strong><\/td><td>\u2248 16 %<\/td><td>Limitada por las horas solares, irradiaci\u00f3n, clima, orientaci\u00f3n y p\u00e9rdidas.<\/td><\/tr><tr><td><strong>E\u00f3lica terrestre<\/strong><\/td><td>\u2248 36 %<\/td><td>Depende fuertemente del recurso e\u00f3lico, rotor, altura de buje y emplazamiento.<\/td><\/tr><tr><td><strong>E\u00f3lica marina<\/strong><\/td><td>\u2248 41 %<\/td><td>Los recursos offshore suelen ser m\u00e1s fuertes y constantes, aunque las paradas pueden ser m\u00e1s complejas.<\/td><\/tr><tr><td><strong>Hidr\u00e1ulica<\/strong><\/td><td>\u2248 43 %<\/td><td>Muy dependiente de hidrolog\u00eda, tipo de central, almacenamiento y gesti\u00f3n del agua.<\/td><\/tr><tr><td><strong>CSP<\/strong><\/td><td>\u2248 22 %<\/td><td>Puede aumentar mucho con almacenamiento t\u00e9rmico, pero depende del dise\u00f1o y recurso solar directo.<\/td><\/tr><tr><td><strong>Geotermia<\/strong><\/td><td>\u2248 85 %<\/td><td>Puede operar de forma continua con elevada disponibilidad si el recurso es estable.<\/td><\/tr><tr><td><strong>Bioenerg\u00eda<\/strong><\/td><td>\u2248 78 %<\/td><td>Puede ser despachable, pero depende de combustible, mantenimiento y econom\u00eda de operaci\u00f3n.<\/td><\/tr><tr><td><strong>Nuclear<\/strong><\/td><td>\u2248 86 % de mediana global<\/td><td>Opera normalmente muchas horas al a\u00f1o; las grandes paradas de mantenimiento tienen fuerte impacto.<\/td><\/tr><\/tbody><\/table><p><span style=\"text-decoration: underline;\"><span style=\"color: #000080; text-decoration: underline;\"><a style=\"color: #000080; text-decoration: underline;\" href=\"https:\/\/www.irena.org\/Publications\/2026\/Jul\/Renewable-Power-Generation-Costs-in-2025\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>IRENA<\/strong><\/a> <\/span><\/span>report\u00f3 para 2025 factores de capacidad globales medios del 16 % para solar fotovoltaica, 36 % para e\u00f3lica terrestre, 41 % para e\u00f3lica marina, 43 % para hidr\u00e1ulica, 22 % para CSP, 85 % para geotermia y 78 % para bioenerg\u00eda. En nuclear, la <span style=\"text-decoration: underline;\"><span style=\"color: #000080; text-decoration: underline;\"><a style=\"color: #000080; text-decoration: underline;\" href=\"https:\/\/www-pub.iaea.org\/MTCD\/publications\/PDF\/RDS-2-45_web.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>IAEA<\/strong><\/a> <\/span><\/span>indic\u00f3 una mediana global de <strong>86,4 %<\/strong> en 2024 para los reactores operativos que reportaron datos.<\/p><p>Estas cifras deben utilizarse como referencias agregadas, no como objetivos de ingenier\u00eda. Una planta solar en una regi\u00f3n de irradiaci\u00f3n excepcional puede superar ampliamente el promedio global, mientras otra situada en una latitud menos favorable puede quedar por debajo y seguir funcionando perfectamente. Lo mismo ocurre con e\u00f3lica, hidro y el resto de tecnolog\u00edas.<\/p><h3>Factor de capacidad en solar fotovoltaica<\/h3><p>En fotovoltaica existe un matiz especialmente importante: qu\u00e9 potencia se utiliza en el denominador. Una planta puede describirse como 100 MWac en el punto de conexi\u00f3n y tener, por ejemplo, 130 MWp DC de m\u00f3dulos. Si el factor de capacidad se calcula sobre 100 MWac ser\u00e1 mayor que si se calcula sobre 130 MWp DC. Por esta raz\u00f3n, cualquier comparaci\u00f3n seria debe indicar si se utiliza capacidad AC neta, capacidad DC instalada u otra referencia. En mercados el\u00e9ctricos y estad\u00edsticas de generaci\u00f3n suele ser m\u00e1s habitual utilizar la capacidad AC de la planta, mientras que en ingenier\u00eda fotovoltaica el<span style=\"text-decoration: underline;\"><span style=\"color: #000080; text-decoration: underline;\"> <a style=\"color: #000080; text-decoration: underline;\" href=\"https:\/\/energyear.com\/es\/diccionario-energetico\/yield-energetico-energy-yield-assessment-fotovoltaica\/\"><strong>specific yield<\/strong><\/a> <\/span><\/span>y el Performance Ratio permiten analizar el rendimiento desde otras perspectivas.<\/p><p>El DC\/AC ratio tambi\u00e9n influye. Sobredimensionar el campo DC permite que el inversor opere cerca de su potencia nominal durante m\u00e1s horas, elevando el factor de capacidad AC, aunque a cambio puede aumentar el clipping durante horas de irradiaci\u00f3n elevada. Los <span style=\"text-decoration: underline;\"><span style=\"color: #000080;\"><a style=\"color: #000080;\" href=\"https:\/\/energyear.com\/es\/diccionario-energetico\/tracker-solar\/\"><strong>trackers solares<\/strong><\/a><\/span><\/span> tambi\u00e9n pueden elevar la producci\u00f3n anual al extender la curva de generaci\u00f3n durante ma\u00f1ana y tarde.<\/p><h3>Factor de capacidad en e\u00f3lica<\/h3><p>En e\u00f3lica, el factor de capacidad depende principalmente de la distribuci\u00f3n de velocidades de viento y de c\u00f3mo se relaciona esa distribuci\u00f3n con la curva de potencia del aerogenerador. No basta con conocer la velocidad media anual: dos emplazamientos con la misma media pueden producir de forma diferente si uno tiene un recurso m\u00e1s estable y el otro alterna periodos de calma con vientos muy fuertes.<\/p><p>El di\u00e1metro del rotor, la altura de buje, la densidad del aire, las p\u00e9rdidas por estela, disponibilidad mec\u00e1nica y restricciones ambientales o de red tambi\u00e9n son determinantes. Los aerogeneradores modernos con rotores mayores pueden obtener factores de capacidad superiores porque capturan m\u00e1s energ\u00eda a velocidades moderadas, incluso sin aumentar proporcionalmente la potencia nominal.<\/p><h3>Factor de capacidad en hidr\u00e1ulica, geotermia, nuclear y t\u00e9rmica<\/h3><p>En hidr\u00e1ulica, el factor puede variar enormemente entre una central de pasada, una planta con gran embalse y una instalaci\u00f3n dise\u00f1ada principalmente para cubrir picos. Un factor bajo no implica necesariamente bajo valor: una hidroel\u00e9ctrica que produce solo en horas de alta demanda puede tener una funci\u00f3n estrat\u00e9gica mucho mayor que otra que maximiza MWh.<\/p><p>Geotermia y nuclear suelen registrar factores altos porque pueden operar de forma continua durante largos periodos. Sin embargo, una parada programada de varias semanas puede reducir significativamente la cifra anual. En generaci\u00f3n t\u00e9rmica de gas o carb\u00f3n, el valor depende tanto de disponibilidad t\u00e9cnica como de decisiones de despacho, costes de combustible, precios del CO\u2082, penetraci\u00f3n renovable y estructura del mercado. Una central perfectamente disponible puede tener un factor de capacidad bajo simplemente porque pocas horas resulta econ\u00f3micamente \u00f3ptimo producir.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ae53ae0 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"ae53ae0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h2>Factor de capacidad no es eficiencia<\/h2><p>Esta es una de las confusiones m\u00e1s habituales. La eficiencia mide qu\u00e9 proporci\u00f3n de la energ\u00eda de entrada se convierte en energ\u00eda \u00fatil. El factor de capacidad mide cu\u00e1nto se utiliza la potencia nominal a lo largo del tiempo. Son conceptos completamente distintos.<\/p><p>Una central de ciclo combinado puede tener una eficiencia t\u00e9rmica superior al 60 % y un factor de capacidad del 20 % si funciona pocas horas. Una planta solar convierte \u00fanicamente una fracci\u00f3n de la radiaci\u00f3n recibida en electricidad, pero puede tener un factor de capacidad perfectamente competitivo para su tecnolog\u00eda. Comparar tecnolog\u00edas usando \u00fanicamente uno de estos indicadores conduce a conclusiones err\u00f3neas.<\/p><h2>Factor de capacidad vs disponibilidad<\/h2><p>La disponibilidad indica cu\u00e1nto tiempo un activo est\u00e1 t\u00e9cnicamente preparado para producir. El factor de capacidad indica cu\u00e1nta energ\u00eda produjo realmente respecto al m\u00e1ximo te\u00f3rico. Un parque e\u00f3lico puede tener una disponibilidad del 98 % y un factor de capacidad del 35 % porque durante muchas horas no hay suficiente viento.<\/p><p>Lo contrario tambi\u00e9n ayuda a entender la relaci\u00f3n: una planta geot\u00e9rmica con recurso constante puede alcanzar un factor de capacidad cercano a su disponibilidad porque, cuando est\u00e1 operativa, produce de forma relativamente continua. Por eso la disponibilidad es uno de los factores que influyen en el capacity factor, pero no son la misma m\u00e9trica. Una estrategia eficaz de <a href=\"https:\/\/energyear.com\/es\/diccionario-energetico\/om-operacion-mantenimiento-energias-renovables\/\"><strong>O&amp;M<\/strong><\/a> busca precisamente reducir p\u00e9rdidas de disponibilidad y recuperar producci\u00f3n.<\/p><h2>Factor de capacidad vs Performance Ratio<\/h2><p>En solar fotovoltaica, el Performance Ratio (PR) mide el rendimiento t\u00e9cnico de la instalaci\u00f3n comparando la energ\u00eda real con la que cabr\u00eda esperar a partir de la irradiaci\u00f3n disponible. El factor de capacidad, en cambio, compara la producci\u00f3n real con el m\u00e1ximo te\u00f3rico que resultar\u00eda de operar a potencia nominal las 24 horas del d\u00eda. Esto significa que el PR permite aislar mejor las p\u00e9rdidas del sistema respecto al recurso solar, mientras que el factor de capacidad incorpora indirectamente que de noche no hay producci\u00f3n y que la irradiaci\u00f3n cambia a lo largo del a\u00f1o. Una planta puede tener un PR excelente y un factor de capacidad relativamente bajo simplemente por estar situada en una regi\u00f3n con menos irradiaci\u00f3n.<\/p><h2>Factor de capacidad vs capacity credit<\/h2><p>Otro concepto distinto es el capacity credit o contribuci\u00f3n a la capacidad firme. El factor de capacidad indica cu\u00e1nta energ\u00eda genera una tecnolog\u00eda en promedio a lo largo del tiempo, mientras el capacity credit intenta estimar cu\u00e1nto puede contribuir de forma fiable durante las horas cr\u00edticas del sistema.<\/p><p>Una planta solar puede tener un factor de capacidad anual razonable, pero aportar poca capacidad firme si el pico de demanda se produce despu\u00e9s de la puesta de sol. Del mismo modo, un activo con un factor de capacidad relativamente bajo puede tener un gran valor de capacidad si est\u00e1 disponible precisamente durante periodos de escasez.<\/p><h2>C\u00f3mo afecta el curtailment al factor de capacidad<\/h2><p>El <span style=\"text-decoration: underline;\"><span style=\"color: #000080; text-decoration: underline;\"><a style=\"color: #000080; text-decoration: underline;\" href=\"https:\/\/energyear.com\/es\/diccionario-energetico\/curtailment-energia-que-es-causas-tipos\/\"><strong>curtailment<\/strong><\/a> <\/span><\/span>reduce la energ\u00eda efectivamente exportada aunque el recurso estuviera disponible. Por tanto, si el factor se calcula con la energ\u00eda neta entregada a red, el curtailment reduce directamente el capacity factor observado. Esta diferencia puede ser muy relevante en zonas con alta penetraci\u00f3n renovable. Un proyecto puede disponer de un recurso excelente y una disponibilidad t\u00e9cnica elevada, pero terminar con un factor de capacidad inferior al previsto debido a congesti\u00f3n de red, restricciones operativas o precios negativos que hacen conveniente reducir producci\u00f3n.<\/p><h2>\u00bfEs siempre mejor un factor de capacidad alto?<\/h2><p>No necesariamente. Un factor alto indica un mayor aprovechamiento energ\u00e9tico de la potencia instalada, pero no mide por s\u00ed solo el valor econ\u00f3mico de esa energ\u00eda. Lo importante es combinarlo con el precio al que se vende la electricidad, los costes de operaci\u00f3n, inversi\u00f3n, disponibilidad y flexibilidad.<\/p><p>Una central que produce casi continuamente puede registrar un factor de capacidad elevado pero vender muchos MWh a precios bajos. Otra planta con un factor menor puede concentrar su generaci\u00f3n en horas de elevada demanda y obtener mayores ingresos por MW instalado. Esta diferencia es especialmente importante en sistemas con alta penetraci\u00f3n renovable y precios horarios muy variables. Tambi\u00e9n debe evitarse utilizar el factor de capacidad como una comparaci\u00f3n directa de \u201ccalidad\u201d entre tecnolog\u00edas. Solar, e\u00f3lica, nuclear, hidro y gas cumplen funciones diferentes dentro del sistema. El factor de capacidad ayuda a entender su producci\u00f3n energ\u00e9tica, pero no sustituye m\u00e9tricas como LCOE, disponibilidad, flexibilidad, emisiones, capacidad firme o valor de mercado.<\/p><h2>Por qu\u00e9 el factor de capacidad es clave para evaluar un proyecto energ\u00e9tico<\/h2><p>En un modelo financiero, peque\u00f1as variaciones del factor de capacidad pueden modificar de forma importante los ingresos esperados porque afectan directamente al volumen de MWh disponibles para vender. Por eso los estudios de producci\u00f3n, recurso y p\u00e9rdidas buscan estimar esta variable con precisi\u00f3n antes de tomar una decisi\u00f3n de inversi\u00f3n.<\/p><p>En solar y e\u00f3lica, un <span style=\"text-decoration: underline;\"><span style=\"color: #000080;\"><a style=\"color: #000080;\" href=\"https:\/\/energyear.com\/es\/diccionario-energetico\/yield-energetico-energy-yield-assessment-fotovoltaica\/\"><strong>Energy Yield Assessment<\/strong><\/a><\/span><\/span> permite modelizar producci\u00f3n esperada, incertidumbres y escenarios como P50 o P90. A partir de esas estimaciones puede derivarse el factor de capacidad esperado del proyecto y compararlo con plantas similares.<\/p><p>La m\u00e9trica tambi\u00e9n resulta \u00fatil para detectar problemas durante operaci\u00f3n. Si un activo que hist\u00f3ricamente produc\u00eda con un factor del 35 % cae al 29 % sin un cambio equivalente en el recurso, puede existir un problema de disponibilidad, degradaci\u00f3n, p\u00e9rdidas, curtailment o rendimiento que merece ser investigado. Por eso, m\u00e1s que una cifra aislada, el capacity factor es especialmente potente cuando se analiza junto con series hist\u00f3ricas y otras m\u00e9tricas operativas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36892e9 elementor-widget__width-initial elementor-widget elementor-widget-post-info\" data-id=\"36892e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"post-info.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-inline-items elementor-icon-list-items elementor-post-info\">\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-repeater-item-5e5f915 elementor-inline-item\" itemprop=\"about\">\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-tags\"><\/i>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-terms\">\n\t\t\t\t\t\t\t<span class=\"elementor-post-info__item-prefix\">Etiquetas:<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-post-info__terms-list\">\n\t\t\t\t<a href=\"https:\/\/energyear.com\/it\/tag\/capacity-factor\/\" class=\"elementor-post-info__terms-list-item\">Capacity Factor<\/a>, <a href=\"https:\/\/energyear.com\/it\/tag\/disponibilidad\/\" class=\"elementor-post-info__terms-list-item\">disponibilidad<\/a>, <a href=\"https:\/\/energyear.com\/it\/tag\/energia-eolica\/\" class=\"elementor-post-info__terms-list-item\">energ\u00eda e\u00f3lica<\/a>, <a href=\"https:\/\/energyear.com\/it\/tag\/energia-renovable\/\" class=\"elementor-post-info__terms-list-item\">energ\u00eda renovable<\/a>, <a href=\"https:\/\/energyear.com\/it\/tag\/factor-de-capacidad\/\" class=\"elementor-post-info__terms-list-item\">Factor de capacidad<\/a>, <a href=\"https:\/\/energyear.com\/it\/tag\/produccion-energetica\/\" class=\"elementor-post-info__terms-list-item\">producci\u00f3n energ\u00e9tica<\/a>, <a href=\"https:\/\/energyear.com\/it\/tag\/rendimiento-energetico\/\" class=\"elementor-post-info__terms-list-item\">rendimiento energ\u00e9tico<\/a>, <a href=\"https:\/\/energyear.com\/it\/tag\/solar-fotovoltaica\/\" class=\"elementor-post-info__terms-list-item\">solar fotovoltaica<\/a>\t\t\t\t<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>El Capacity Factor o factor de capacidad mide la energ\u00eda real producida frente al m\u00e1ximo te\u00f3rico de un activo. Descubre su f\u00f3rmula, c\u00f3mo se calcula, qu\u00e9 factores lo afectan y valores t\u00edpicos por tecnolog\u00eda.<\/p>","protected":false},"author":14,"featured_media":93057,"comment_status":"open","ping_status":"open","sticky":false,"template":"elementor_header_footer","format":"standard","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"categories":[178],"tags":[446,450,449,295,445,447,451,448],"class_list":["post-93037","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-diccionario-energetico","tag-capacity-factor","tag-disponibilidad","tag-energia-eolica","tag-energia-renovable","tag-factor-de-capacidad","tag-produccion-energetica","tag-rendimiento-energetico","tag-solar-fotovoltaica"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Factor de capacidad: qu\u00e9 es, f\u00f3rmula y c\u00f3mo se calcula | Energyear<\/title>\n<meta name=\"description\" content=\"Descubre qu\u00e9 es el factor de capacidad o Capacity Factor, su f\u00f3rmula, c\u00f3mo se calcula, qu\u00e9 factores lo afectan y valores t\u00edpicos en solar, e\u00f3lica, hidro y m\u00e1s.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/energyear.com\/it\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Factor de capacidad: qu\u00e9 es, f\u00f3rmula y c\u00f3mo se calcula | Energyear\" \/>\n<meta property=\"og:description\" content=\"Descubre qu\u00e9 es el factor de capacidad o Capacity Factor, su f\u00f3rmula, c\u00f3mo se calcula, qu\u00e9 factores lo afectan y valores t\u00edpicos en solar, e\u00f3lica, hidro y m\u00e1s.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/energyear.com\/it\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/\" \/>\n<meta property=\"og:site_name\" content=\"Energyear\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-17T16:08:02+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-17T16:35:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/energyear.com\/wp-content\/uploads\/2026\/11\/capacity-factor-factor-capacidad-que-es-calculo.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2000\" \/>\n\t<meta property=\"og:image:height\" content=\"1333\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Energyear SL\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"Energyear SL\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"12 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/energyear.com\\\/diccionario-energetico\\\/capacity-factor-factor-capacidad-que-es-calculo\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/energyear.com\\\/diccionario-energetico\\\/capacity-factor-factor-capacidad-que-es-calculo\\\/\"},\"author\":{\"name\":\"Energyear SL\",\"@id\":\"https:\\\/\\\/energyear.com\\\/es\\\/#\\\/schema\\\/person\\\/0e9d50001a4910a218795dd9b822c8f8\"},\"headline\":\"Capacity Factor o factor de capacidad: qu\u00e9 es, f\u00f3rmula y c\u00f3mo se calcula\",\"datePublished\":\"2026-11-17T16:08:02+00:00\",\"dateModified\":\"2026-11-17T16:35:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/energyear.com\\\/diccionario-energetico\\\/capacity-factor-factor-capacidad-que-es-calculo\\\/\"},\"wordCount\":2733,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/energyear.com\\\/es\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/energyear.com\\\/diccionario-energetico\\\/capacity-factor-factor-capacidad-que-es-calculo\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/energyear.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/capacity-factor-factor-capacidad-que-es-calculo.jpg\",\"keywords\":[\"Capacity Factor\",\"disponibilidad\",\"energ\u00eda e\u00f3lica\",\"energ\u00eda renovable\",\"Factor de capacidad\",\"producci\u00f3n energ\u00e9tica\",\"rendimiento energ\u00e9tico\",\"solar fotovoltaica\"],\"articleSection\":[\"Diccionario energ\u00e9tico\"],\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/energyear.com\\\/diccionario-energetico\\\/capacity-factor-factor-capacidad-que-es-calculo\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/energyear.com\\\/diccionario-energetico\\\/capacity-factor-factor-capacidad-que-es-calculo\\\/\",\"url\":\"https:\\\/\\\/energyear.com\\\/diccionario-energetico\\\/capacity-factor-factor-capacidad-que-es-calculo\\\/\",\"name\":\"Factor de capacidad: qu\u00e9 es, f\u00f3rmula y c\u00f3mo se calcula | Energyear\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/energyear.com\\\/es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/energyear.com\\\/diccionario-energetico\\\/capacity-factor-factor-capacidad-que-es-calculo\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/energyear.com\\\/diccionario-energetico\\\/capacity-factor-factor-capacidad-que-es-calculo\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/energyear.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/capacity-factor-factor-capacidad-que-es-calculo.jpg\",\"datePublished\":\"2026-11-17T16:08:02+00:00\",\"dateModified\":\"2026-11-17T16:35:42+00:00\",\"description\":\"Descubre qu\u00e9 es el factor de capacidad o Capacity Factor, su f\u00f3rmula, c\u00f3mo se calcula, qu\u00e9 factores lo afectan y valores t\u00edpicos en solar, e\u00f3lica, hidro y m\u00e1s.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/energyear.com\\\/diccionario-energetico\\\/capacity-factor-factor-capacidad-que-es-calculo\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/energyear.com\\\/diccionario-energetico\\\/capacity-factor-factor-capacidad-que-es-calculo\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/energyear.com\\\/diccionario-energetico\\\/capacity-factor-factor-capacidad-que-es-calculo\\\/#primaryimage\",\"url\":\"https:\\\/\\\/energyear.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/capacity-factor-factor-capacidad-que-es-calculo.jpg\",\"contentUrl\":\"https:\\\/\\\/energyear.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/capacity-factor-factor-capacidad-que-es-calculo.jpg\",\"width\":2000,\"height\":1333,\"caption\":\"Capacity Factor o factor de capacidad: qu\u00e9 es, f\u00f3rmula y c\u00f3mo se calcula\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/energyear.com\\\/diccionario-energetico\\\/capacity-factor-factor-capacidad-que-es-calculo\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/energyear.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Capacity Factor o factor de capacidad: qu\u00e9 es, f\u00f3rmula y c\u00f3mo se calcula\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/energyear.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/energyear.com\\\/es\\\/\",\"name\":\"Energyear\",\"description\":\"Eventos de Energ\u00edas Renovables y Movilidad\",\"publisher\":{\"@id\":\"https:\\\/\\\/energyear.com\\\/es\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/energyear.com\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/energyear.com\\\/es\\\/#organization\",\"name\":\"Energyear\",\"url\":\"https:\\\/\\\/energyear.com\\\/es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/energyear.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/energyear.com\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/logo_energyear_f.svg\",\"contentUrl\":\"https:\\\/\\\/energyear.com\\\/wp-content\\\/uploads\\\/2022\\\/01\\\/logo_energyear_f.svg\",\"width\":100,\"height\":100,\"caption\":\"Energyear\"},\"image\":{\"@id\":\"https:\\\/\\\/energyear.com\\\/es\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/energyear.com\\\/es\\\/#\\\/schema\\\/person\\\/0e9d50001a4910a218795dd9b822c8f8\",\"name\":\"Energyear SL\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/energyear.com\\\/wp-content\\\/litespeed\\\/avatar\\\/43a3da17ec6a1ff96601a7d947b79cb9.jpg?ver=1795438013\",\"url\":\"https:\\\/\\\/energyear.com\\\/wp-content\\\/litespeed\\\/avatar\\\/43a3da17ec6a1ff96601a7d947b79cb9.jpg?ver=1795438013\",\"contentUrl\":\"https:\\\/\\\/energyear.com\\\/wp-content\\\/litespeed\\\/avatar\\\/43a3da17ec6a1ff96601a7d947b79cb9.jpg?ver=1795438013\",\"caption\":\"Energyear SL\"},\"url\":\"https:\\\/\\\/energyear.com\\\/it\\\/author\\\/marketing\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Fattore di capacit\u00e0: che cos\u2019\u00e8, formula e calcolo | Energyear","description":"Scopri che cos\u2019\u00e8 il fattore di capacit\u00e0 o Capacity Factor, la formula, come si calcola, quali fattori lo influenzano e i valori tipici nel solare, nell\u2019eolico, nell\u2019idroelettrico e in altre tecnologie.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/energyear.com\/it\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/","og_locale":"it_IT","og_type":"article","og_title":"Factor de capacidad: qu\u00e9 es, f\u00f3rmula y c\u00f3mo se calcula | Energyear","og_description":"Descubre qu\u00e9 es el factor de capacidad o Capacity Factor, su f\u00f3rmula, c\u00f3mo se calcula, qu\u00e9 factores lo afectan y valores t\u00edpicos en solar, e\u00f3lica, hidro y m\u00e1s.","og_url":"https:\/\/energyear.com\/it\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/","og_site_name":"Energyear","article_published_time":"2026-11-17T16:08:02+00:00","article_modified_time":"2026-11-17T16:35:42+00:00","og_image":[{"width":2000,"height":1333,"url":"https:\/\/energyear.com\/wp-content\/uploads\/2026\/11\/capacity-factor-factor-capacidad-que-es-calculo.jpg","type":"image\/jpeg"}],"author":"Energyear SL","twitter_card":"summary_large_image","twitter_misc":{"Scritto da":"Energyear SL","Tempo di lettura stimato":"12 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/energyear.com\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/#article","isPartOf":{"@id":"https:\/\/energyear.com\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/"},"author":{"name":"Energyear SL","@id":"https:\/\/energyear.com\/es\/#\/schema\/person\/0e9d50001a4910a218795dd9b822c8f8"},"headline":"Capacity Factor o factor de capacidad: qu\u00e9 es, f\u00f3rmula y c\u00f3mo se calcula","datePublished":"2026-11-17T16:08:02+00:00","dateModified":"2026-11-17T16:35:42+00:00","mainEntityOfPage":{"@id":"https:\/\/energyear.com\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/"},"wordCount":2733,"commentCount":0,"publisher":{"@id":"https:\/\/energyear.com\/es\/#organization"},"image":{"@id":"https:\/\/energyear.com\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/#primaryimage"},"thumbnailUrl":"https:\/\/energyear.com\/wp-content\/uploads\/2026\/11\/capacity-factor-factor-capacidad-que-es-calculo.jpg","keywords":["Capacity Factor","disponibilidad","energ\u00eda e\u00f3lica","energ\u00eda renovable","Factor de capacidad","producci\u00f3n energ\u00e9tica","rendimiento energ\u00e9tico","solar fotovoltaica"],"articleSection":["Diccionario energ\u00e9tico"],"inLanguage":"it-IT","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/energyear.com\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/energyear.com\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/","url":"https:\/\/energyear.com\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/","name":"Fattore di capacit\u00e0: che cos\u2019\u00e8, formula e calcolo | Energyear","isPartOf":{"@id":"https:\/\/energyear.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/energyear.com\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/#primaryimage"},"image":{"@id":"https:\/\/energyear.com\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/#primaryimage"},"thumbnailUrl":"https:\/\/energyear.com\/wp-content\/uploads\/2026\/11\/capacity-factor-factor-capacidad-que-es-calculo.jpg","datePublished":"2026-11-17T16:08:02+00:00","dateModified":"2026-11-17T16:35:42+00:00","description":"Scopri che cos\u2019\u00e8 il fattore di capacit\u00e0 o Capacity Factor, la formula, come si calcola, quali fattori lo influenzano e i valori tipici nel solare, nell\u2019eolico, nell\u2019idroelettrico e in altre tecnologie.","breadcrumb":{"@id":"https:\/\/energyear.com\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/energyear.com\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/energyear.com\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/#primaryimage","url":"https:\/\/energyear.com\/wp-content\/uploads\/2026\/11\/capacity-factor-factor-capacidad-que-es-calculo.jpg","contentUrl":"https:\/\/energyear.com\/wp-content\/uploads\/2026\/11\/capacity-factor-factor-capacidad-que-es-calculo.jpg","width":2000,"height":1333,"caption":"Capacity Factor o factor de capacidad: qu\u00e9 es, f\u00f3rmula y c\u00f3mo se calcula"},{"@type":"BreadcrumbList","@id":"https:\/\/energyear.com\/diccionario-energetico\/capacity-factor-factor-capacidad-que-es-calculo\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/energyear.com\/es\/"},{"@type":"ListItem","position":2,"name":"Capacity Factor o factor de capacidad: qu\u00e9 es, f\u00f3rmula y c\u00f3mo se calcula"}]},{"@type":"WebSite","@id":"https:\/\/energyear.com\/es\/#website","url":"https:\/\/energyear.com\/es\/","name":"ENERGYEAR","description":"Eventos de Energ\u00edas Renovables y Movilidad","publisher":{"@id":"https:\/\/energyear.com\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/energyear.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/energyear.com\/es\/#organization","name":"ENERGYEAR","url":"https:\/\/energyear.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/energyear.com\/es\/#\/schema\/logo\/image\/","url":"https:\/\/energyear.com\/wp-content\/uploads\/2022\/01\/logo_energyear_f.svg","contentUrl":"https:\/\/energyear.com\/wp-content\/uploads\/2022\/01\/logo_energyear_f.svg","width":100,"height":100,"caption":"Energyear"},"image":{"@id":"https:\/\/energyear.com\/es\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/energyear.com\/es\/#\/schema\/person\/0e9d50001a4910a218795dd9b822c8f8","name":"Energyear SL","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/energyear.com\/wp-content\/litespeed\/avatar\/43a3da17ec6a1ff96601a7d947b79cb9.jpg?ver=1795438013","url":"https:\/\/energyear.com\/wp-content\/litespeed\/avatar\/43a3da17ec6a1ff96601a7d947b79cb9.jpg?ver=1795438013","contentUrl":"https:\/\/energyear.com\/wp-content\/litespeed\/avatar\/43a3da17ec6a1ff96601a7d947b79cb9.jpg?ver=1795438013","caption":"Energyear SL"},"url":"https:\/\/energyear.com\/it\/author\/marketing\/"}]}},"_links":{"self":[{"href":"https:\/\/energyear.com\/it\/wp-json\/wp\/v2\/posts\/93037","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/energyear.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/energyear.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/energyear.com\/it\/wp-json\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/energyear.com\/it\/wp-json\/wp\/v2\/comments?post=93037"}],"version-history":[{"count":5,"href":"https:\/\/energyear.com\/it\/wp-json\/wp\/v2\/posts\/93037\/revisions"}],"predecessor-version":[{"id":93065,"href":"https:\/\/energyear.com\/it\/wp-json\/wp\/v2\/posts\/93037\/revisions\/93065"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/energyear.com\/it\/wp-json\/wp\/v2\/media\/93057"}],"wp:attachment":[{"href":"https:\/\/energyear.com\/it\/wp-json\/wp\/v2\/media?parent=93037"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/energyear.com\/it\/wp-json\/wp\/v2\/categories?post=93037"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/energyear.com\/it\/wp-json\/wp\/v2\/tags?post=93037"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}